4-13. Preflow Time Control

2
Use control to set length of time (0.2, 0.4, 0.6,
0.8, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5 or 5.0
seconds) gas flows before welding starts.
1
Process Control
2
Power Switch
3
Meters
To change preflow time, proceed as follows:
TM-359 Page 44
1
Turn power off. Push and hold Process Con-
trol button and turn On power. Hold button for
approximately 7 seconds (or until software
version number_ _ _ _ _ _-_ clears meters).
The TIG LED will light and the meters will dis-
play [o.2] [SEL]. The factory preflow default
setting is 0.2 seconds. To change preflow
3
00.2
SEL
time, press and release Process Control but-
ton until desired time is displayed on meters.
Application:
Preflow is used to purge the immediate weld
area of atmosphere. Preflow also aids in con-
sistent arc starting.