Engine Maintenance Parts - Lincoln Electric Power-Arc 5500 Operator's Manual

Hide thumbs Also See for Power-Arc 5500:
Table of Contents

Advertisement

D-3
CLEAN OR REPLACE SPARK PLUG: Clean or
replace the spark plug after every 100 hours of opera-
tion or every season, whichever comes first. Do not
blast the spark plug clean with an abrasive cleaning
device. Clean the plug by scraping it or by using a
wire brush. Wash the plug with a commercial sol-
vent. After cleaning or when installing a new spark
plug, set the terminal gap to .030 inch (.76 mm) with a
feeler gauge. See Figure D.5.
FIGURE D.5 - SET SPARK PLUG GAP
Use the engine owner's manual for latest Plug Gap Info.
CLEAN SPARK ARRESTER SCREEN: Refer to the
engine owner's manual that was shipped with your
POWER-ARC 5500 for the proper cleaning instruc-
tions.
Refer to Table D.1 for engine maintenance parts. The part numbers are accurate at the time of printing. (Verify
the current part number by referring to the engine ownerʼs manual.
Replace or clean engine maintenance parts per the interval outlined in the engine ownerʼs manual.
MAINTENANCE
2
1

ENGINE MAINTENANCE PARTS

PART
SPARK PLUG
(RESISTOR)
FUEL FILTER
AIR CLEANER PANEL
(Pleated Paper)
AIR PRE-CLEANER
(AS NEEDED)
POWER-ARC 5500
TABLE D.1
ROBIN / SUBARU PART #
NGK BR6 HS
NONE
279-32616-00
279-32611-00
(CAN BE CLEANED AND REUSED AS NEEDED)
D-3