Appendix; Checkout Procedure Log - Omron F3S-TGR-CL-K2C Installation And Operation Manual

Body protection sensor safety light curtain
Table of Contents

Advertisement

17-1 Checkout procedure log

57
The following checkout procedure must be performed by qualified personnel
during initial F3S-TGR-CL system installation and at least every three months
or more frequently depending on machine usage and company guidelines.
Item
Verify that the guarded machine is compatible with
the type of machine which may be used with the
F3S-TGR-CL system. See the chapter "Safety pre-
cautions" on page ix for further information.
Verify that the mounting distance of the F3S-TGR-
CL system is equal to or greater than the minimum
safe distance from the danger point. See the chapter
"Safe Mounting Distance" on page 16 for further
information.
Determine that all access to the danger point not pro-
tected by the F3S-TGR-CL system is guarded by
other means, such as gates, fencing or other
approved methods. Verify that all additional guarding
devices are installed and operating properly.
Make sure the operator is not able to stand between
the F3S-TGR-CL system detection zone and the
machine danger point. Verify that the light curtain
can only be reset from a position outside and within
view of the hazardous machine area.
Inspect the electrical connections between the
guarded machine's control system and the F3S-
TGR-CL system. Verify that they are properly con-
nected to the machine such that a stop signal from
the F3S-TGR-CL system results in an immediate halt
of the machine's cycle. See the chapter "Connection
to the Machine control circuit" on page 24 for further
information.
If the EDM monitoring feature is not used, proceed to
the next step. To test the EDM feature, verify that the
feature has been enabled. Turn the machine power
on. Cycle the machine. Place a temporary jumper
wire between the EDM connections. The F3S-TGR-
CL should enter an alarm condition. Remove the
temporary jumper. Press and release the test button.
Record the test results in the machine log, then per-
form the test procedure.
Technician's Signature ___________________________________________
SECTION 17

Appendix

Condition
Comments
@
Pass
@
Fail
@
Pass
@
Fail
@
Pass
@
Fail
@
Pass
@
Fail
@
Pass
@
Fail
@
Pass
@
Fail
@
Pass
@
Fail