Omron F3S-TGR-CL-K2C Installation And Operation Manual page 57

Body protection sensor safety light curtain
Table of Contents

Advertisement

Specification
AOPD(ESPE)
Safety category
Safety Integrity Level
Performance level (PL)
Mean time to dangerous fail-
ure (MTTFd)
Diagnostic Coverage (DC)
Mean time to repair (MTTR)
PFH
Proof test interval
Conformity
F3S-TGR-CL2:
Type 2 acc. to EN/IEC 61496-1 (2004) and EN/IEC
61496-2 (2006)
F3S-TGR-CL4: Type 4 acc. to EN/IEC 61496-1
(2004) and EN/IEC 61496-2 (2006)
F3S-TGR-CL2 system is suitable for safety control
systems up to Category 2 acc. EN954-1 (1996)
F3S-TGR-CL4 system is suitable for safety control
systems up to Category 4 acc. EN954-1 (1996)
F3S-TGR-CL system is suitable for up to SIL 3 per
IEC 61508
F3S-TGR-CL2 system is suitable for safety control
systems up to Performance level c acc. EN ISO
13849-1
F3S-TGR-CL4 system is suitable for safety control
systems up to Performance level e acc. EN ISO
13849-1
450 years
High acc. EN ISO 13849-1
8 hours
-09
2.5 * 10
Every 20 years
Section 14-1
43