Muting and override
11-1-5-3 X-activation mode
!WARNING
!WARNING
32
• d is the distance between the F3S-TGR-CL system and the sensor con-
nected to Muting A input. This distance represents the minimum length of
the material to be detected.
Timing requirements and limitations:
• If Muting A is activated, Muting B must be activated within 120 sec. to
activate the muting function. Otherwise muting function is stopped.
• Muting A and Muting B cannot be activated at the same time. A minimum
time difference equal to the response time of the sensor is mandatory.
• If Muting A and Muting B are activated, the protective field must be
obscured within 120 sec. Otherwise the muting function is stopped.
• Maximum muting time is 600 sec. After this time, muting function is
stopped even if the Muting inputs are still active or the protective field is
still obscured.
• The F3S-TGR-CL allows that Muting A or Muting B drop for a maximum
time of 200 ms without stopping the muting function. A time longer than
200 ms is detected as a muting stop.
• The F3S-TGR-CL allows that the protective field becomes free for a max-
imum time of 200 ms in Muting condition. If the protective field is free for
more than 200 ms, the muting function stops.
SLC
Free
Interrupted
ON
OSSD
OFF
ON
Muting
Input A
OFF
Muting
ON
Input B
OFF
Muting
Active
Status
OFF
RT< TM < 120s
The X-muting activation mode can be used in applications where material is
transported only in one direction. This muting mode is used in applications,
where eg. pallets are used to carry stacked boxes or crates. Most stable
detection of this kind of material is possible using the X-muting activation
mode.
Two muting sensors are connected to the two Muting inputs, Muting A and
Muting B.
This muting activation mode can only used in uni-directional transport. Failure
to do so may result in serious injury.
The crossing point of the two muting sensors MUST be inside the dangerous
zone. Failure to do so may result in serious injury.
120s