B. CONNECTION OF 120 VOLT POWER SUPPLY
WARNING
!
Disconnect 120 volt AC. Failure to follow these
instructions could create a shock hazard
causing death or severe personal injury.
1. Connect white to white; black to black; and green to
green or bare copper wire using appropriate sized
twist connectors. Tape the twist wire connectors to
the supply wire to assure they don't vibrate off.
WARNING
!
This appliance is equipped with a 3-wire
(grounded) system for protection against
shock hazard. Make sure that the appliance is
wired into a properly grounded 120 volt AC cir-
cuit and the polarity is correct. Failure to do so
could result in death, personal injury or dam-
age to the equipment.
2. Push the wires into the box and tighten the strain
relief.
3. Install the cover (part of the mounting hardware) with
the one blunt point screw provided.

8. AIR BOX INSTALLATION

A. Remove the two filter-grilles from the air box. See FIG. 12.
FIG. 12
Remove Filter Grill
B. Slide the air box over the ceiling template. See FIG. 13.
FIG. 13
Slide Air Box Over
Template
C. Install the four (4) sharp pointed screws through the air
box legs and into the pre-punched holes in ceiling tem-
plate. See FIG. 14.
Note: There are four optional mounting holes on the outer
edge of the return air opening for which no screws are
provided. These are only required where an uneven ceiling
does not allow proper fitting of the air box.
D. Install the filter-grilles by pushing them into place.
See FIG. 14.
E. Turn on power to the air conditioner for operational
check.
PENGUIN AIR BOX INSTALLATION INSTRUCTORS FOR ANALOG CONTROLS
FIG. 14
Push Filter In Place
FIG. 15
Air Conditioner
Roof Opening
Analog
Relay
Box
Mounting
Bolts
Air Box
9
Install
Screws
Roof Mount Assembly
Upper
Discharge
Duct
Ceiling