Operating Principle - Lincoln Electric AMBICLEAN 5000 Safety Instruction For Use And Maintenance

Table of Contents

Advertisement

OPERATING PRINCIPLE

This system sets the fume cloud into motion, catches it, filters it and recycles it into the workshop. Thus, the fumes
do not have the time to cool and drop, making the working environment clean.
Motor frequency converter
HEPA H13 42M² filter
HEPA H13 42M² filter
NB: The AMBICLEAN does not release the operator from using personal protection, because even if the
atmosphere in the workshop is healthy, the worker is not protected during the welding process. We recommend
either the use of fume extraction torches or the use of ventilated masks of the Zephyr type, independent masks
with a supply of filtered and controlled area.
Saturation alarm:
The AMBICLEAN ESSENTIAL 5000 are fitted with an alarm system that controls the saturation status of the filter
cassettes. The pressure difference through the cassettes is continuously monitored. When the difference exceeds
500 Pa, a red indicator goes on and a buzzer sounds.
In such a case, the filter continues to operate but in degraded mode, and the filter cassettes must absolutely be
changed.
-8
Operating principle of the unclogging filter
Polluted air is distributed in the filter after passing
1
through the pre-filter compartment.
Filter cassettes purify the air up to 99.9% and
2
more.
The filtered air is expelled through the blowing
3
nozzles on the front of the Ambiclean
Le coffret de commande est équipé d'un variateur de
fréquence qui permet de maintenir un débit constant
grace à la mesure continue de pression dynamique du
ventilateur de l' AMBICLEAN.
8695 8472 / A
AMBICLEAN 5000

Advertisement

Table of Contents
loading