(1) Test Data
Set between 0 and 272 bytes of test data (communications buffer holds up to
289 bytes of test data) within the following ranges according to the communi-
cations data length setting.
Data length
8 bits
ASCII code 20H to 7EH, A1H to FEH
7 bits
ASCII code 20H to 7EH
(2) Response Code
Response
code (hex)
1001
Command length too long
2203
Operation error
0000
Normal end
This service is used to execute operation commands.
Service Request PDU
MRC
SRC
Operation
Related
code
information
3
0
0
5
2
2
2
2
Service Response PDU
MRC
SRC
Response
code
3
0
0
5
2
2
4
(1) Operation Code and Related Information
Operation code
06
Software reset
There is no response (i.e., service response PDU) for a software reset.
Response Code
Response
code (hex)
1001
Command too long
1002
Command too short
1100
Parameter error
2203
Operation error
0000
Normal completion
(3) Explanation and Precautions
Software Reset
Processing is restarted from the reset routine when the power is turned ON.
There is no response (i.e., no service response PDU) for a software reset
only. Responses are returned for all other operation codes.
Test data
Name
The command is too long.
EEPROM error
No errors were found.
Description
00
Name
The command is too long.
The command is too short.
The operation code or related
information is not correct.
• Unable to execute command.
Refer to (3) Explanation and
Precautions below for details.
• EEPROM error
No errors were found.