Case Front Controls - Lincoln Electric Maverick 325X Operator's Manual

Table of Contents

Advertisement

MAVERICK
325X
®
6
7
8
12
14

CASE FRONT CONTROLS

1. LCD SCREEN, IP67 RATED OPERATOR A - The LCD screen
displays information about welding mode, output voltage or
current, engine status and machine settings. It allows
operator to select welding mode and read the output voltage
or current when presetting using the output control knob.
During welding, the screen displays the actual output
voltage (VOLTS) and current (AMPS). A memory feature
holds the screens on for 5 seconds after welding is stopped.
This allows the operator to read the actual current and
voltage just prior to when welding was ceased. In engine
status section, information about engine hours, filter
condition, engine oil and other service items are displayed.
2. GLOW PLUG PUSH BUTTON - When pushed activates the
GLOW PLUGS. Glow plug should not be activated for more
than 20 seconds continuously.
3. START PUSH BUTTON - Energizes the starter motor to crank
the engine.
4. RUN / STOP SWITCH - RUN position energizes the engine prior
to starting. STOP position stops the engine. The oil pressure
FIGURE A.3 - CASE FRONT CONTROLS
1
3
2
interlock switch prevents battery drain if the switch is left in
the RUN position and the engine is not operating.
5. BATTERY CIRCUIT BREAKER - For protection of battery
charging circuit.
6. USB PORT - Allows the customer to update their welders by
uploading new software via USB drive through front panel.
7. 6-PIN REMOTE CONTROL CONNECTOR - For attaching
optional remote control equipment. Includes auto sensing
remote control circuit.
8. 7-PIN SPOOL GUN CONNECTION - For attaching optional
spool gun equipment. Includes contactor closure circuit and
auto sensing remote control circuit.
9. OUTPUT CONTROL - The OUTPUT KNOB is used to preset the
output voltage or current as displayed on the LCD screen for
the six welding modes. When in the ARC GOUGING or CV-WIRE
modes and when a remote control is connected to the 6-Pin or
14-Pin Connector, the auto sensing circuit automatically
switches the OUTPUT CONTROL from control at the welder to
the remote control. The knob is also used for settings and
setup manipulation.
A-7
INSTALLATION
5
16
9
10
11
12
13
15

Advertisement

Table of Contents
loading

This manual is also suitable for:

12797

Table of Contents