Fostex PD-4 Owner's Manual page 30

Portable digital audio recorder
Hide thumbs Also See for PD-4:
Table of Contents

Advertisement

Additions to the PD-4 Owner's Manual
In relation to version up (V1.03) of the PD-4 software, the following items were added in the SETUP mode
of this equipment. Aa the newly added functions are explained only here, please read this together with
the main text.
SETUP mode additional functions
1. Setup of the pause mode disengage time [SU104] (New addition)
Previously, the pause mode disengage time was fixed at 3 minutes but with
addition of "SU 104" in the SETUP mode, the disengage time can be set to
several different lengths.
Time setting can be selected from 30 seconds, 1,2, 3, 4 and 5 minutes by
their assigned numbers as listed below (Initial setting is "03.")
10 HP cl
UJ
I
00
I Disengaged after 30 seconds.
I
01
i Disengaged after 1 minute.
i
02
i Disengaged after 2 minutes.
1.03.(1 ; Disengaged after 3 minutes.
I
04
! Disengaged after 4 minutes.
1
05
1 Disengaged after 5 minutes.
2
.
Two items on output conditions and the setup mode "02" [SU 110] are
added to the ON/OFF setting of error tone output.
When the mode is set to "01" (ON) the error tone output conditions are
THE TAPE REMAINDER WHEN RECORDING BECOMES LESS THAN 5
MINUTES and WHEN EXT TC iS INTERRPTED. These have been added
and an error tone will now be output for about 3 seconds when either one of
the output conditions have been met.
Furthermore, "02" has been added to the setup mode in which the error tone
can be made to sound only when the recording tape remainder becomes less
than 5 minutes and when the power supply voltage is erroneous. Details on
the setup numbers are as follows (Initial setting is "01.")
/ /
OE In 01
I'"'PQ' * X ALL
.I
i 01 (*) i ON (Output when BAR LOW, TAPE REMA
I..
'■
1.02.].ON ^joutputonjXw^^^