EXCELL PRECISION CO., LTD.
NOTE 4
(a) The number of the weight UNITS (Max: 5, key in 1 ~ 5)
(b) The weight UNITS for weight calibration (choose from "kg", "g", "lb", key in 0, 1, or 2)
Parameter description:
0 kg , 1 g , 2 lb
NOTE 5
(c) ( d) (e) ( f ) ( g) ( h)
c ~ h set the maximum capacity (6 digits)
i ~ n set the mass value for weight calibration (6 digits)
The maximum capacity needs to be presented based on the decimal system, and the
first UNITS must be the calibration UNITS.
For example: How to calculate the maximum capacity and the mass value based on
the different types of weight UNITS.
A. Choose "kg" as the weight UNITS for the weight calibration
The first weight UNITS setting: 6.000 kg / 0.002 kg
Enter the maximum capacity 006000 at (c) ~ (h)
Enter the mass value 006000 at (i) ~ (n)
UNITS "lb" (hexadecimal notation system)
Calibration weight is 6kg. 0.001 kg = 0.002204623 lb
6 kg = 62.204623 (lb) = 13.227738 lb. Take 12 lb as the max capacity
12.0.00 lb / 0.08 oz (minimum division=8, decimal point position=2)
12 lb 16 (oz) = 192.00 oz Enter the maximum capacity 019200 at (c) ~ (h)
13.227738 lb 16 (oz) = 211.64 oz
UNITS "GN"
Calibration weight is 6kg. 0.001 kg = 15.432358GN
6kg=92594GN
The maximum capacity 100000GN Enter the maximum capacity 100000 at (c) ~ (h)
020359XX
(a) (b)
Enter the mass value 021164 at (i) ~ (n)
Enter the calibration weight 092594 at (i) ~ (n)
(i) ( j ) (k ) ( l) ( m ) ( n)
23
ZSME300000434