Jenn-Air JDRP548WP02 Installation Instructions Manual page 12

30" (76.2 cm), 36" (91.4 cm) and 48" (121.9 cm) commercial style dual fuel convection ranges
Hide thumbs Also See for JDRP548WP02:
Table of Contents

Advertisement

Available languages

Available languages

5.
4-wire connection: Power supply cord
6.
Use this method for:
7
New branch-circuit installations (1996 NEC)
3.
12
Mobile homes
Connect the other 2 wires (lines 1 and 2) to the outer
aluminum terminal blocks.
Securely tighten screws for proper electrical connection.
Tighten strain relief screws.
Replace terminal block cover.
Recreational vehicles
3-wire connection: Power supply cord
In an area where local codes prohibit grounding through the
neutral
the ground-link screw. Bend the ground link away from the
range so that it does not contact the range.
2
A. Ground-link screw
B. Ground link bent away from range
Connect the green ground wire from the power supply cord to
the range using the ground-link screw. The ground wire must
be attached first and must not contact any other terminal.
Use a %4" nut driver to remove the hex washer head screws
from the terminal blocks.
Connect the neutral (center) wire to the center terminal
connector using one of the hex washer head screws.
Securely tighten screw for proper electrical connection.
3.
D
4
NY
5
A
ee
A. Line 1
F. Ground link
B. Green ground wire
C. Ground-link screw
D. Hex washer head screw
E. Silver-colored terminal
block screw
G. Neutral (center) wire
H. Line 2
|. UL listed strain relief and
40- or 50-amp range
power supply cord
Use this method only if local codes permit connecting cabinet-
ground conductor to neutral wire of power supply cord.
Remove the ground-link screw from the range frame. Save
1.
Use a %" nut driver and remove the hex washer head screws
from the aluminum terminal blocks.
Connect the neutral (center) wire to the center terminal
connector using one of the hex washer head screws.
Securely tighten screw for proper electrical connection.
A. Line 1
B. Ground link
C. Hex washer head screw
D. Silver-colored terminal
block screw
E, Neutral (center) wire
F. Line 2
G. UL listed strain relief
and 40- or 50-amp range
power supply cord
Connect the other 2 wires (lines 1 and 2) to the outer terminal
screws on the terminal block.
Tighten strain relief screws.
Replace terminal block cover.