166
To adjust the operating pressure:
1.
Pull the pressure regulator (1) up.
2.
Turn the pressure regulator until the pressure gage (2)
indicates the proper setting:
• Increase pressure = turn clockwise
• Reduce pressure = turn counterclockwise
3.
Push the pressure regulator (1) down.
6.3.2

Draining the water-oil mixture

NOTICE
Property damage from excess water!
Excess water can cause damage to the machine.
Drain water as required.
Water condensation accumulates in the water separator (2) of
the pressure controller.
Water-oil mixture.
Proper setting
The water-oil mixture must not rise up to the level of the filter
element (1).
Check the level of the water-oil mixture (2) in the collection tray
on a daily basis.
Operating Instructions D888 e-con - 00.0 - 12/2023