6.3 Power Sequences

6.3.1 TO_SAFE_SEVERE
The TO_SAFE_SEVERE sequence will shut down all rails without. The sequence immediately ceaseses BUCK
switching and enables the pulldown resistors of the BUCKs and LDOs. This is to prevent any damage of the
PMICs in case of over voltage on VCCA or thermal shutdown. The timing is illustrated in
SLVUBY7A – OCTOBER 2020 – REVISED OCTOBER 2022
Submit Document Feedback
Copyright © 2022 Texas Instruments Incorporated
Pre-Configurable Finite State Machine (PFSM) Settings
Figure
Powering DRA821 with TPS6594-Q1 and LP8764-Q1
6-2.
29