Product Description - GEM 4240 Operating Instructions Manual

Combi switchbox
Hide thumbs Also See for 4240:
Table of Contents

Advertisement

Prior to commissioning:
1. Transport and store the product correctly.
2. Do not paint the bolts and plastic parts of the product.
3. Carry out installation and commissioning using trained
personnel.
4. Provide adequate training for installation and operating
personnel.
5. Ensure that the contents of the document have been fully
understood by the responsible personnel.
6. Define the areas of responsibility.
7. Observe the safety data sheets.
8. Observe the safety regulations for the media used.
During operation:
9. Keep this document available at the place of use.
10. Observe the safety information.
11. Operate the product in accordance with this document.
12. Operate the product in accordance with the specifications.
13. Maintain the product correctly.
14. Do not carry out any maintenance work and repairs not de-
scribed in this document without consulting the manufac-
turer first.
In cases of uncertainty:
15. Consult the nearest GEMÜ sales office.

3 Product description

3.1 Construction
3
4
5
Item
Name
1
Housing cover
2
Housing base
3
Electrical connection
4
Adapter piece
5
Mounting kit, valve spe-
cific
Seals
www.gemu-group.com
1
2
Materials
PC
PPS
SS, PP
SS
SS, PP
NBR
3.2 Description
The GEMÜ 4240 combi switchbox is suitable for mounting to
pneumatically operated linear actuators. The position of the
valve spindle is reliably detected electronically and reported
via microswitches or proximity switches, using play-free and
non-positive mounting. Integrated pilot valves enable direct
activation of the process valve connected to them. The
product has been designed specially for valves with a stroke
of 5 to 75 mm.
3.3 Function
The GEMÜ 4240 combi switchbox indicates the current posi-
tion of the valve. When the valve is opened, the spindle in the
combi switchbox moves upwards and indicates that the valve
is OPEN using the communication interface. When the valve is
closed, the spring in the mounting kit presses the spindle in
the combi switchbox downwards and indicates that the valve
is CLOSED using the communication interface.
5 / 23