3.5.4 System Application - Air Handler System
Make-up Water
Backflow Preventer
Pressure Reducing Valve
System application drawings are intended to explain the system piping concept only.
Note
Install a filter in the system return to remove foreign objects from the system. Foreign objects inside
the system may result in abnormal system operation.
Refer to "3.3 Filling the System" on page 26 for make-up water connections and refer to the
requirements of your local codes to ensure compliance.
Air handlers with an internal pump shall be piped either with a crossover pipe at the AHU or in a
primary/secondary configuration with the boiler.
Refer to the "3.6.9 Wiring Diagram - Air Handler" on page 43 for wiring connections.
You can use a secondary piping configuration for the air handler system to maintain optimal flow
and heat capacity.
32
Installing the System Piping
Air Separator
Air Flow
Air Handler
System Pump
(Boiler Pump)
Expansion Tank