Navien NHB H Series Installation And Operation Manual page 121

Table of Contents

Advertisement

Included Items:
Gas Orifice (Table 1)
Gas Pressure and Conversion Kit Number Labels
NHB-055/080H Orifice Identification
Gas
NG
Type
Altitude
0-5,399 ft
Orifice
Factory
Installed
Orifice
4.10/4.15
Size
Kit No.
-
NHB-110H Orifice Identification
Gas
NG
Type
Altitude
0-5,399 ft
Orifice
Factory
Installed
Orifice
4.35/5.20
Size
Kit No.
-
NHB-150H Orifice Identification
Gas
NG
Type
Altitude
0-5,399 ft
Orifice
Factory
Installed
Orifice
4.45/6.25
Size
Kit No.
-
Table 1. Orifice Size
LP
5,400-
0-10,100 ft
10,100 ft
For High
For LP
altitude
4.30/4.40
3.40/3.50
NAC-
NAC-
NH055/080
L055/080
LP
5,400-
0-10,100 ft
10,100 ft
For High
For LP
altitude
4.60/5.50
3.65/4.30
NAC-NH110 NAC-L110
LP
5,400-
0-10,100 ft
10,100 ft
For High
For LP
altitude
4.70/6.60
3.65/5.05
NAC-NH150 NAC-L150
Please confirm the installation elevation
Note
by using the provided QR code to
access the following website (https://
www.navieninc.com/elevation) and
entering the proper zip/postal code.
WARNING
Fire and Explosion Hazard
To prevent serious injury or death:
Be careful not to confuse the PROPANE GAS &
HIGH ALTITUDE CONVERSION KIT. Do NOT use
the NATURAL GAS HIGH ALTITUDE CONVERSION
KIT for NG when converting to PROPANE gas.
Make sure that the conversion is completed
with the proper orifice. If the installed orifice
does not conform to the specifications in Table
1, incomplete combustion may occur, resulting
in personal injury or property damage.
Appendixes