3.5.2 System Application - Zone System with Zone Valves (Primary/Secondary Piping)
Make-up Water
Backflow Preventer
Pressure Reducing Valve
Expansion Tank
System application drawings are intended to explain the system piping concept only.
Note
Install a filter in the system return to remove foreign objects from the system. Foreign objects inside
the system may result in abnormal system operation.
Refer to "3.3 Filling the System" on page 26 for make-up water connections and refer to the
requirements of your local codes to ensure compliance.
Use a pump with an integral check valve or install a check valve at the pump outlet.
Refer to "3.6.5 Wiring Diagram - Zone Valve System" on page 39 for wiring connections.
30
Installing the System Piping
Zone #2
Zone #1
Zone Valve (Typical)
System Pump
Air Separator
Additional Zone
Not to exceed 4 pipe Dia or Max. 12"
Boiler Pump