ELECTRIC COMBI OVENS - SERVICE PROCEDURES AND ADJUSTMENTS
CODE
RELAY
01
K1
door motor
02
K2
cavity vent motor
03
K3, K6
contactor KM1 (half power, full speed)
04
K3
cooling fan(s) and door light only
05
K3, K4
water injection solenoid (humidifier)
06
K5
drain pump
07
K3, K5
water fill solenoid
contactor KM2 (half power, half speed);
08
K3, K7
on 20 levels only, contactor KM3 and
drain cool down solenoid.
contactor KM3 and drain cool down
solenoid on 6 & 10 levels; contactor
09
K3, K8
KM5 on 20 levels only.
(steam generator heating elements)
contactor KM7 (convection heating
10
K3, K10
elements on 10 & 20 levels)
contactor KM6
11
K3, K9
(convection heating elements)
5.
t1 is displayed in the time display and the actual cavity temperature is displayed in the temperature display.
Verify the probes are sensing temperature correctly. Rotate the adjustment knob and select the probe
temperature to display (T1 = cavity probe (top on 20 levels); T2 = bottom cavity probe (20 levels only); T3 =
cooking probe).
6.
To exit the diagnostic test mode, press and hold the START key for approximately 3 seconds.

SERVICE ERROR LIGHTS

1.
There are four lights at the bottom of the
control. When lit, they tell the operator that the
oven needs service related to the component
that the light(s) represent. Refer to
"TROUBLESHOOTING" for display error
codes.
The lights are, from left to right.
A.
Water supply.
B.
Convection heat.
C.
Steam generator heat.
D.
Cavity fan.
COMPONENT
Page 29 of 68
TEST
Door magnetic reed switch. Result will be displayed
automatically. Rotate the door handle to change the
condition. Press and hold the TEMP key to close the
door; release to open.
Cavity vent micro switch. Result will be displayed
automatically. Press and hold the TEMP key to
change condition.
Convection fan motor value - press and hold the
TEMP key for 30 sec. to test the fan motor
configuration settings. The test result will be
displayed .
Cavity Hi Limits and steam generator thermal
fuse(s). Press and hold the TEMP key for result.
Visual - water injection into cavity.
Water level sensors (water level in steam generator)
Water level sensors (water level in steam generator)
NOTE: If the steam generator thermal fuse(s) or the
cavity high limits open, the steam generator heat
and the convection heat error lights will come on.
2.
Turn the oven off and reset the oven control.
A.
Programmable control - press the off key.
B.
Manual controls - rotate the selector switch
to the off position.
3.
Correct the problem related to the service error
light. See "TROUBLESHOOTING" section.
4.
Turn the oven on and check operation.
A.
Programmable control - press the on key,
select a heating mode and press start key
to begin.
B.
Manual controls - rotate the selector switch
to one of the three heating modes.
NOTE: On water supply errors, monitor the oven for
at least 5 minutes to pass the "time out" period for
the steam generator fill.
CONDITION
0 = open;
1 = closed
0 = open;
1 = closed
0 = incorrect;
1 = correct.
0 = open;
1 = closed
0 = unsatisfied;
1 = satisfied