FULL SIZE GAS CONVECTION OVEN - REMOVAL AND REPLACEMENT OF PARTS

INTERIOR LIGHTS

electrical power to the machine and
follow lockout / tagout procedures.
Do not touch the Halogen lamp with bare
hands. If lamp is exposed to oil from the skin, the life
will be reduced. Ensure lamp is free from oil and dirt
before replacing.
Bulb Replacement
1.
Pull lamp cover off.
2.
Grasp lamp using a clean cloth and remove from
lamp assembly.
Fig. 33
3.
Reverse procedure to install new bulb.
Lamp Assembly Replacement
1.
Remove racks.
2.
Pull lamp cover off.
3.
Remove RIGHT SIDE REAR PANEL.
Insert screw driver and push lamp assembly out
into cavity.
Disconnect the
Page 15 of 35
Fig. 34
4.
Disconnect wires.
5.
Reverse procedure to install new lamp assembly.

COOLING FAN

electrical power to the machine and
follow lockout / tagout procedures.
1.
Remove RIGHT SIDE FRONT PANEL.
NOTE: If right side - front panel is not accessible, this
component can be serviced by removing CONTROL
PANEL.
2.
Remove wire nuts from fan wire connections.