Reference Information

This section provides procedures for mounting the DTP3 T 202 and the DTP3 R 201 as well as disconting the
ground between them.

Mounting the Devices

Internal Settings
Mounting the Devices
ATTENTION:
Installation and service must be performed by authorized personnel only.
L'installation et l'entretien doivent être effectués par le personnel autorisé uniquement.
Risk of property damage.
Risque de dommages matériels.
The devices can be set on a table, mounted in a rack, or mounted under a desk or table.

Tabletop Use

Four adhesive rubber feet are included with each device. For tabletop use, attach one foot at each corner on the
bottom of the devices, and place them where desired.

Mounting Kits

Mount the unit using any optional compatible mounting kit listed on the Extron website (www.extron.com), in
accordance with the directions included with the kit. For rack mounting, see "UL Rack-Mounting Guidelines,"
below.

UL Rack-Mounting Guidelines

The following Underwriters Laboratories (UL) guidelines pertain to the safe installation of the transmitter or
receiver into a rack.
CAUTION:
Elevated operating ambient temperature — If installed in a closed or multi-unit rack assembly, the
operating ambient temperature of the rack environment may be greater than room ambient
temperature. Therefore, install the equipment in an environment compatible with the maximum ambient
temperature (TMA = +122°F, +50°C) specified by Extron.
Reduced air flow — Install the equipment in a rack so that the amount of air flow required for safe
operation of the equipment is not compromised.
Mechanical loading — When mounting the equipment in the rack, ensure that uneven mechanical
loading does not cause a hazardous condition.
Circuit overloading — When connecting the equipment to the supply circuit, consider the effect that
circuit overloading might have on overcurrent protection and supply wiring. Consider equipment
nameplate ratings when addressing this concern.
Reliable earthing (grounding) — Maintain reliable grounding of rack-mounted equipment. Pay
particular attention to supply connections other than direct connections to the branch circuit (for
example, use of power strips).
DTP3 T 202 / DTP3 R 201 • Reference Information
27