Supply Cord Position; Neo / Neo Wifi Regulating Box Position - Nexus NEO Manual

Ambient temperature & power regulator control
Table of Contents

Advertisement

5.4.2 SUPPLY CORD POSITION

The supply cord must be connected to a proper
socket or to a non-switched fused spur (without
an intermediate plug for NEO / NEO WIFI
supplied without plug) which must be at least 25
cm from the floor according to the wiring
regulations in force in the country where the
installation is carried out. Figure 4 shows
examples of positioning of the system.

5.4.3 NEO / NEO WIFI REGULATING BOX POSITION

• NEO / NEO WIFI must only be fitted vertically in the bottom part of the towel rail.
• Electrical towel rail must NOT be installed with the NEO / NEO WIFI regulating box
located at the top. This can seriously damage the control box and create a dangerous
situation with a risk of fire.
• NEO / NEO WIFI must be installed at distance of 40 mm (minimum) and 80 mm
(maximum) from the wall. Figure 5 shows the optimal positions for the NEO / NEO WIFI.
Figure 3
Figure 4 NEO / NEO WIFI positioning
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

Neo wifi

Table of Contents