Hearth Stove Installation

NOTE:
This type of installation requires a
full reline (positive connection).
Interior or Exterior
Masonry Chimney
NOTE:
This type of installation requires a
UBC-approved masonry
connector or other method
approved by the NFPA 211
Standard. See Chimney
Connector Requirements on
page 10 for further details.
WARNING:
We recommend that a minimum
3' chimney be added to the
minimum system height for every
1' of horizontal run.
© Travis Industries
Stove Installation
NOTE: The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes
(UBC, etc.). Damage must be
repaired prior to installation. The
chimney must be 15' (4.57M) to
33' (10.05M) tall.
Combustible
Mantle
Floor Protection
(See the section
"Floor Protection
Requirements"
for more details)
(for qualified installers only)
Min. 36"
(915mm)
8/15/2023 -1593
17
Cap and flashing
prevents water from
entering
The liner must be
stainless steel connector
or flexible vent. Follow
the liner manufacturer's
instructions for installation
and support.
Remove damper
or wire it open
See the section
"Stove Placement
Requirements" for
minimum clearances
required.
IDB1125
Rockport NGH