12
Stove Installation
Chimney Termination Requirements
•
Must have an approved cap (to prevent water from entering)
•
Must not be located where it will become plugged by snow or other material
•
Must terminate at least 3' (914mm) above the roof and at least 2' (610mm) above any portion of the
roof within 10' (3.048M) (see below
Outside Air Requirements
•
Required for mobile homes (US) or transportable buildings (CAN) & in certain localities (check with
building officials).
•
Must not be drawn from an enclosed space (garage, unventilated crawl space). May be drawn from
ventilated crawl space (a) or the exterior of the home (b). Must have suitable rodent/debris screen
and rain protection (hood) (c).
•
Requires the optional outside air kit (sku# 99200139) – see below.
•
Air duct maximum length is 15' (4.57M) with a minimum cross section of 16 square inches
(10323mm) or 6' (1.83M) with a minimum cross section of 7 square inches (4517mm).