Ground The System; Complete The Installation; Connect Air Supply - Graco ProBell Instructions Manual

Hide thumbs Also See for ProBell:
Table of Contents

Advertisement

Installation
Ground the
the System
System
Ground
Ground
the
System
When operating the electrostatic bell, any
ungrounded objects in the spray location (people,
containers, tools, etc.) can become electrically
charged. Improper grounding can result in static
sparking, which can cause a fire, explosion, or
electric shock.
Ground all equipment, personnel, object being
sprayed, and conductive objects in or close to the
spray location. Follow the grounding instructions
below.
For full system grounding instructions and
requirements, see your applicator manual (334452 or
334626). The ground wire from the applicator must
be connected to the ground lug on the electrostatic
controller or stand. All cart components are
connected together for grounding. Connect a ground
wire from the grounding lug on the Electrostatic
Controller or stand to a true earth ground.
Figure 1 Ground on an Electrostatic System
14
Figure 2 Ground on a Non-Electrostatic System
Complete the
the Installation
Installation
Complete
Complete
the
Installation
If a complete system (Pxxxxx) was purchased,
lines and cables (except fluid) are connected to the
appropriate controller at the factory. To complete the
setup and installation of the rotary applicator and
system, follow the instructions in the ProBell Rotary
Applicator manuals.
Connect Air
Air Supply
Supply
Connect
Connect
Air
Supply
NOTICE
NOTICE
NOTICE
Air that is not filtered to specification can clog
bearing air passages and cause bearing failure.
See the ProBell applicator manual for filter
requirements.
1. Required air filters have been installed on the
cart at the factory.
2. Connect the air supply to the main air inlet on
your air controller.
Note
Once air is applied it flows freely out of
Port B on the Speed Controller.
3A4232D