C. SPECIFICATIONS
Model #
B-VENT
3'
8"
4'
8"
5'
8"
6'
10"
7'
10"
8'
10"
WARNING: NON-COMBUSTIBLE ZONE: USE ONLY NON-COMBUSTIBLE MATERIAL IN THIS AREA FOR ENTIRE WIDTH OF
FIREPLACE. DO NOT USE WOOD, SHEETROCK, ETC., IN THIS ZONE.
NOTE: OTHER CLEARANCES APPLY. ALL CLEARANCES MUST BE MAINTAINED.
Refer to Section 4 (Framing), Section 5 (Non-combustible Zone) and Section 10 (Finishing) for more information.
NOTE: The qualified installer should follow the procedure best suited for the installation.
D. INSTALLATION OVERVIEW
1.
Frame should be built after the fireplace is installed or extra clearance must be planned for at the intake collar. Framing must allow for vent
installation.
2.
If masonry (optional) will be used, prepare foundation for the masonry load. A lintel is required to support the added weight above the fireplace.
3.
Install hearth if desired.
4.
Insert fireplace into framing.
5.
Double check clearances to combustibles.
6.
Complete gas line installation.
7.
Complete electrical hook-up.
8.
Complete venting installation.
9.
Install facing material, mantel or cabinetry.
10. Install glass media/natural stone, and any interior options including mirrors and/or driftwood log set.
11. Verify proper operation of fireplace and all components.
E. PLACEMENT CLEARANCE REQUIREMENTS
This fireplace must be installed on a level surface capable of supporting the fireplace and venting.
Fireplace must be placed directly on wood or non-combustible surface (not linoleum or carpet) extending entire depth and width of fireplace.
This fireplace may be installed in a bedroom.
Non-Combustible Materials Specifications
Material which will not ignite and burn.
Such materials are those consisting entirely of steel, iron, brick, tile, concrete,
slate, glass or plasters, or any combination thereof.
Materials that are reported as passing ASTM E 136, Standard Test
Method for Behavior of Materials in a Vertical Tube
Furnace at 750 ºC shall be considered non-combustible materials.
Page 10
3 - SPECIFICATIONS
OA
REG PV
10"
RS12
10"
RS12
10"
RS12
10"
RS14
10"
RS14
12"
RS14
IN-LINE PV
BTU'S
RSIF160
40,000
RSIF160
60,000
RSIF160
80,000
RSIF180
100,000
RSIF180
120,000
RSIF180
140,000
Combustible Materials Specifications
Materials made of or surfaced with wood, compressed paper, plant fibers,
plastics, or other material that can ignite and burn, whether flame proofed or
not, or plastered shall be considered combustible materials.
ORIFICE
ORIFICE
NG
Propane
(2X) #43
(2X) #55
(3X) #43
(3X) #55
(4X) #43
(4X) #55
(5X) #43
(5X) #55
(6X) #43
(6X) #55
(7X) #43
(7X) #55
INS_CUST UL REV E