6.3 Getting into Fast Test Cycle

1
Enter diagnostic mode.
2
Press the >> CYCLE button twice. The EXTRA DRY, qUICk and SANITIZE modifier LED's will be lit.
3
Press START button to run the fast cycle, and the Heavy, Eco and Rinse LED's will be lit.
While in diagnostic menu
4
Close the tub within the time frame to allow the cycle to start, 4 seconds for US market, 7 seconds for
all other markets.
5
If you are too slow closing the tub, it will time out, and you will need to press ther START button again
While in diagnostic menu
and close the tub within the given timeframe.
press
twice
press
twice
Press PROGRAM CYCLE button twice.
Extra Dry, Quick and Sanatize LEDs will be lit.
Press PROGRAM CYCLE button twice.
Extra Dry, Quick and Sanatize LEDs will be lit.
Press start button to run fast cycle - the HEAVY, ECO and RINSE LEDs will be lit.
US market - close the tub within 4 seconds to allow to start.
Press start button to run fast cycle - the HEAVY, ECO and RINSE LEDs will be lit.
AA market / ROW - close the tub within 4 seconds to allow to start.
US market - close the tub within 4 seconds to allow to start.
Failure to close drawer within these timeframes, it will auto time out. START will need to be pressed again.
AA market / ROW - close the tub within 4 seconds to allow to start.

Getting into Continuous Cycle

Failure to close drawer within these timeframes, it will auto time out. START will need to be pressed again.
1
Enter diagnostics mode.
2
Press the >> CYCLE button 3 times to get into the continous cycle mode. The qUICk and SANITIZE
LED's will be lit.
3
Press the START button to enter the menu, the selected cycle will flash. To select the cycle you want
to run continously press the >>CYCLE button until the LED is lit.
4
Press the START button and close the tub in the time frame required, 4 seconds for US market, 7
While in diagnostic menu
seconds for the other markets.
While in diagnostic menu
three
three
presses
presses
Press PROGRAM CYCLE button three times, Quick and Sanatize LEDs will be lit.
Press PROGRAM CYCLE button three times, Quick and Sanatize LEDs will be lit.
Press START button to enter the menu. The selected PROGRAM CYCLE will flash. To
Press START button to enter the menu. The selected PROGRAM CYCLE will flash. To
select the program cycle you want to run coontinuously, press the PROGRAM CYCLE
select the program cycle you want to run coontinuously, press the PROGRAM CYCLE
button until the LED is lit.
button until the LED is lit.
Press START and close the tub within the time frames:
Press START and close the tub within the time frames:
US = 4 seconds ROW = 7 seconds