Component Testing - Fisher & Paykel DishDrawer DD60 Series Service Manual

Hide thumbs Also See for DishDrawer DD60 Series:
Table of Contents

Advertisement

7.3 Component Testing

Motor Controller
(Back View)
Connector
Motor Controller
(pin numbers on the connectors go from Top to Bottom)
P101
Power
P201
Bottom tub motor phases
Bottom tub element
P202
Top tub motor phases
Top tub element
P203
Bottom tub fill valve
Bottom tub lid motors
P204
Top tub fill valve
Top tub lid motors
Wash Controller
(pin numbers on the connectors go from Right to Left)
P401
Power
P402
Temperature sensor
P405
Rinse aid coil
Drying fan
detergent diverter
P407
water softener bypass valve
Water softener brine pump
7 FAULT DIAGNOSTICS
Device
1&2,2&3,
1&2,2&3,
Note: motor controller is situated
on the inside rear chassis panel
behind bottom tub
P404
P406
P407
Pins
1-2
240 Vac AU, NZ, SG, PF
120 Vac US, TW
8.0 ± 5 Ω (per winding) 16 Ω phase to phase
1&3
4-5
55-60 ± 3 Ω AU, NZ, SG, PF
24-27 ± 3 Ω US,TW
8.0 ± 5 Ω (per winding) 16 Ω phase to phase
1&3
4-5
50 ± 3 Ω AU, NZ, SG, PF
24-27 ± 3 Ω US,TW
1-2
65 ± 10 Ω
3-6
Check between pin 3 & 4, 5 & 6 if open or short circuit
1-2
65 ± 10 Ω
3-6
Check between pin 3 & 4, 5 & 6 if open or short circuit
1-2
24+-5V
1-2
12000 Ω @ 20
8300 Ω @ 30
3000 Ω @ 60
1-2
65 ± 10Ω
5-6
Check if open or short circuit
Note: Run in diagnostics and check fan torque
7-8
65 ± 10Ω
1-2
65 ± 10Ω
(only used on water softener models)
3-4
65 ± 10Ω
(only used on water softener models)
Wash Controller
(Front View)
P402
P410
P403
Description
68
F)
C (
o
o
86
F)
C (
o
o
140
F)
C (
o
o
P405
P401
P408
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents