2-2-15.

Main Code D8

When an error was detected in the file system on the internal memory, the following error occurs.
Main
Sub code
Sub code
code
(1)
(2)
D8
01
ss
2-2-16.

Main Code E1

When an error related to usage restrictions was detected, one of the following errors occurs.
Main
Sub code
Sub code
code
(1)
(2)
E1
01
pp
E1
06
pp
E1
08
pp
E1
09
ss
E1
0A
pp
2-2-17.

Main Code E4

When incorrect installation of the internal memory is detected, one of the following errors occurs.
Main
Sub code
Sub code
code
(1)
(2)
E4
31
00
PWS-4500
Error message
Description
SLOT Mx FILE SYS-
An error was detected in the internal memory file sys-
TEM ERROR
tem. When the same error occurs each time the power
is turned on, the file system must be formatted.
Error message
Description
PORT x COND3 BAD,
Recording was suspended because the alternative sec-
STOP REC
tor of defective sector was fully used on the internal
memory.
PORT x FS STUFFED,
Recording was suspended because the file system of the
STOP REC
internal memory reached the control limit.
PORT x WRITE FAIL,
Recording was suspended to protect data because over-
STOP REC
writing data to the internal memory was attempted.
SLOT Mx CANNOT
An error was detected in the unrecorded area of the in-
REC
ternal memory.
PORT x MAX LENGTH,
The recording time reached the maximum for the PORT
STOP REC
and then recording stopped.
Error message
Description
INTERNAL MEMORY
The internal memory is not accessible because a part of
LACK
or all internal memory cards has/have been removed.
Probable cause: MDC-21 board
Protected operation: None
Probable cause: MDC-21 board
Probable cause: MDC-21 board
Protected operation: Recording is no longer per-
formed.
Probable cause: MDC-21 board
Protected operation: Recording is no longer per-
formed. To make the internal memory recordable,
it must be formatted.
Probable cause: MDC-21 board
Protected operation: Recording is no longer per-
formed. To make the internal memory recordable,
it must be formatted.
Probable cause: Specification of the unit
Protected operation: Recording is no longer per-
formed.
Probable cause: Condition of the installed
MDC-21 boards
Protection: Prohibition of memory access
Continued