Quadra-Fire 4300 Series Installation, Operation & Maintenance Instructions Manual

Quadra-Fire 4300 Series Installation, Operation & Maintenance Instructions Manual

Act wood stove series

Advertisement

Beaverton
Tested and
O-T L
Listed by
Oregon USA
C
OMNI-Test Laboratories, Inc.
This manual contains instructions for Installation, Operation & Maintenance. Please read this entire
manual before you install and use your new room heater. Failure to follow instructions may result in
property damage, bodily injury, or even death.
1) When installing your stove, particular attention should be paid to fire protection. If this room heater is not properly
installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Contact local building,
fire officials or authority having jurisdiction about restrictions, installation inspection and permit requirements in your
area.
2) CAUTION: Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start
or "freshen up" a fire in this heater. Keep all such liquids well away from the heater while it is in use.
3) During operation, if any part of the stove starts to glow, the stove is in an overfired condition. Close the air controls
completely by pulling them out, until the glowing has stopped. OVERFIRING VOIDS YOUR WARRANTY!
4) Cool ashes should be disposed of carefully, using a metal container.
5) Do not burn wet or green wood. Store wood in a dry location.
6) DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE OIL. Do not
burn treated wood, or wood with salt (driftwood, etc.). Burning materials other than wood (including charcoal) under
adverse conditions may generate carbon monoxide in the home, resulting in illness or possible death.
7) Do not permit creosote or soot to accumulate excessively in the chimney or inside the firebox.
8) Check your chimney system thoroughly when installing into an existing metal or masonry chimney. Seek profes-
sional advice if in doubt about its condition.
9) Do not connect this unit to a chimnney flue already serving another appliance.
10) Comply with all minimum clearances to combustibles as shown in this manual for this appliance.
11) Build fire on brick firebox floor. Do not use grates, andirons or other methods to support fuel.
12) HOT WHILE IN OPERATION! Keep children, pets, clothing and furniture away. Contact can cause skin burns.
13) Do not connect to any air distribution duct or system.
14) RISK OF FIRE! Do not operate with stove door or ash removal system door open.
15) For further information refer to NFPA 211 (USA) or CAN/CSA-B365 (Canada).
16) Do not operate without fully assembling all components. Burning your stove wthout the legs attached (if supplied
with unit) will void your warranty, and could present a serious safety hazard.
17) Do not operate with broken glass.
PRIOR TO FIRST FIRE: Remove all labels from glass. Clean plated surfaces with a glass cleanser and soft cloth to
1445 North Highway
Colville, WA 99114
4300 WOOD STOVE SERIES
Advanced Combustion Technology (ACT)
MILLENNIUM
IMPORTANT SAFETY NOTES:
prevent staining from fingerprint oils.
SAVE THESE INSTRUCTIONS
Part 250-7061C
STEP TOP UNI-BODY
December 10, 2004
R
VERY IMPORTANT!!
BEFORE STARTING YOUR
FIRST FIRE READ
HOW TO OPERATE THE
2-STEP DOOR HANDLE
ON PAGE 20
www.quadrafire.com

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire 4300 Series

  • Page 1 4300 WOOD STOVE SERIES Advanced Combustion Technology (ACT) STEP TOP UNI-BODY MILLENNIUM VERY IMPORTANT!! BEFORE STARTING YOUR FIRST FIRE READ HOW TO OPERATE THE 2-STEP DOOR HANDLE Beaverton Tested and O-T L Listed by Oregon USA ON PAGE 20 OMNI-Test Laboratories, Inc. This manual contains instructions for Installation, Operation &...
  • Page 2 Ask your Quadra-Fire Dealer for information on these options. From design, to fabrication, to shipping: Our guarantee of quality is more than a word, it’s Quadra-Fire tradition, and we proudly back this tradition with a Limited Lifetime Warranty.
  • Page 3: Table Of Contents

    4300 ACT Wood Stove Series TABLE OF CONTENTS QUADRA-FIRE 4300 ACT Listings & Safety Cautions ........4 MODEL NAME WOOD STOVE SERIES Installation Materials Needed ......4 Venting System Overview ........4 Uni-Body: ___Step Top ___ Millennium Serial Number Label Location ......5 Dimensions ............
  • Page 4: Listings & Safety Cautions

    LISTINGS & SAFETY CAUTIONS These installation instructions describe the installation and FIRE SAFETY: To provide reasonable fire safety, the following should operation of the QUADRA-FIRE 4300 woodstove. This stove be given serious consideration: meets the U.S. Environmental Protection Agency’s 1990 Install at least one smoke detector on each floor of your home...
  • Page 5: Serial Number Label Location

    4300 ACT Wood Stove Series DIMENSIONS 4300 STEP TOP UNI-BODY PEDESTAL MODEL 26-1/2" (673mm) 34-1/4" 34-1/4" (870mm) (870mm) 8-9/16" (217mm) 10-1/2" (267mm) 15.0" (381mm) 25-3/16" (640mm) 4-3/16" (106mm) 25-3/16" (640mm) 4300 STEP TOP UNI-BODY LEG MODEL 26-1/2" (673mm) 34-1/4" 34-1/4" (870mm) (870mm) 8-9/16"...
  • Page 6: Locating Your Stove

    4300 ACT Wood Stove Series DIMENSIONS 4300 MILLENNIUM MODEL 25-1/2" (648mm) 9-1/2" 12-3/4" 28-1/2" (724mm) (241mm) (324mm) 25-1/2" (648mm) 5-1/2" (140mm) 2-1/4" (57mm) 10-15/16" (278mm) 19-1/16" (484mm) Back of Stove to Glass 14-15/16" (379mm) 15-1/16" (383mm) 24-11/16" (628mm) 31-1/8" (791mm) 18.0"(457mm) 16.0"...
  • Page 7: Clearances To Combustibles

    4300 ACT Wood Stove Series CLEARANCES TO COMBUSTIBLES (UL AND ULC) ALCOVE SIDE VIEW ALCOVE SIDE VIEW 90° OFF TOP 90° OFF TOP UP & OUT CEILING UP & OUT CEILING CLEARANCE CLEARANCE STOVE TO CEILING STOVE TO CEILING CLEARANCE CLEARANCE ALCOVE TOP VIEW CORNER INSTALLATION...
  • Page 8: Floor Protection

    4300 ACT Wood Stove Series FLOOR PROTECTION FLOOR PROTECTION: Floor protector must be noncombustible material, extending beneath heater and to the front/sides/rear as indicated. The floor must be non-combustible or otherwise adequately protected from radiant heat given off by the unit and from sparks and falling embers. A layer of thin brick or ceramic tile over a combustible floor is not sufficient.
  • Page 9: Alternate Materials Worksheet

    4300 ACT Wood Stove Series FLOOR PROTECTION (Cont’d) ALTERNATE MATERIALS WORKSHEET How to determine if alternate floor protection materials are acceptable: All floor protection must be non-combustible (i.e., metals, brick, stone, mineral fiber boards, etc.). Any organic materials (i.e., plastics, wood paper products, etc.) are combustible and must not be used. The floor protection specified includes some form of thermal designation such as R-value (thermal resistance) or k-factor (thermal conductivity).
  • Page 10: Chimney Height / Draft & 2-10-3 Rule

    NOTE: These are guidelines only, and may vary somewhat for individual installations. Your Quadra-Fire stove was designed for and tested on a 6” (152mm) chimney, 12 ft.-14 ft. (360-420cm) high, (includes stove height) measured from the base of the stove. The further your stack height or diameter varies from this configuration, the possibility of performance problems exists.
  • Page 11: Flue Systems & Chimney Connections

    4300 ACT Wood Stove Series FLUE SYSTEMS MASONRY CHIMNEY (Cont’d) There are two separate and different parts to a flue system: the The flue should be checked to determine that it is not too chimney connector and the chimney itself. large for the stove.
  • Page 12: Solid Pack With Metal Supports

    4300 ACT Wood Stove Series SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE For the method of installation to a masonry chimney shown in Figures 14A & 14B on page 14, it will be necessary to purchase a 12” (305mm) long 8" (203mm) inside diameter, section of prefabricated listed solid pack chimney to use as a thimble.
  • Page 13 4300 ACT Wood Stove Series SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE (Cont’d) First, make the frame for the thimble, ensur- ing it is no smaller than 14" (356mm) square, Min. Chimney Clearance Min. Clearance to maintain a 2" (51mm) air space around the to Wall Spacer and 2"...
  • Page 14: Metal Pre-Fab Chimney

    4300 ACT Wood Stove Series CONNECTION TO A METAL PRE-FABRICATED CHIMNEY When a metal prefabricated chimney is used, Listed the manufacturer’s installation instructions Chimney Attic Listed Cap must be followed precisely. You must also Insulation Combustible Shield Maintain 2" (51mm) Storm Collar purchase (from the same manufacturer) and Ceiling...
  • Page 15: Mobile Home

    4300 ACT Wood Stove Series MOBILE HOME INSTALLATION You must use a Quadra-Fire Outside Air Kit Part 831-1780 for installation in a mobile home. An outside air inlet must be provided for combustion and must remain clear of leaves, debris, ice and/or snow. It must be...
  • Page 16: Ash Removal System

    4300 ACT Wood Stove Series ARS OPERATING AND CLEANING ASH REMOVAL SYSTEM (ARS) INSTALLATION 1. When stove is cool, open front door and brush most 1. Place protective pad or stove pallet on floor. of the ash into the center of the firebox. Remember 2.
  • Page 17: Pedestal & Leg Kit Installation

    4300 ACT Wood Stove Series PEDESTAL OR LEG KIT INSTALLATION WARNING: DO NOT OPERATE STOVE BEFORE FULLY ASSEMBLING ALL COMPONENTS. BURNING YOUR STOVE WITHOUT A PEDESTAL OR LEG KIT ATTACHED WILL VOID YOUR WARRANTY AND COULD PRESENT A SAFETY HAZARD. PEDESTAL MODEL 1 Place protective pad or stove pallet on floor.
  • Page 18: Top Shield Installation

    4300 ACT Wood Stove Series INSTALLATION OF OPTIONAL BLOWER, Part 831-1701 The blower is shipped fully assembled and ready for installation. 1. Remove the three bolts (1/4”-20 Phillips Head) on the outer skin at the bottom rear of stove. 2. Align holes in mounting flange of blower with bolt holes in stove. Blower should be positioned around bottom of rear outer skin as shown in drawing below.
  • Page 19: Outside Air Kit

    4300 ACT Wood Stove Series OUTSIDE AIR KIT INSTALLATION Part 831-1780 Included in Kit: 1 front cover; fiberglass rope; 2 vent straps; venting flange & 4 screws; termination cap & screws. Not all materials are needed for each model. MILLENNIUM MODEL Items Needed for Installation: 4”...
  • Page 20: Burning Process

    In order to improve up any large chunks and distribute the coals so that the new the situation, we at Quadra-Fire have developed cleaner-burning wood is laid on hot coals. wood stoves that surpass the requirements for emissions established by our governing agencies.
  • Page 21: Operating Instructions

    4300 ACT Wood Stove Series OPERATING INSTRUCTIONS (Cont’d) IMPORTANT - PLEASE READ BEFORE USING STOVE For maximum operating efficiency with the lowest emissions, follow these operating procedures: Regardless of desired heat output, when loading stove, burn your stove with both air controls wide open for 5 to 15 minutes. Regulate burn rate (heat output) by using the Primary Air Control (center under ashcatcher).
  • Page 22: Opacity

    See blower installation instructions on page 18) If your Quadra-Fire wood stove is equipped with an optional blower, you should follow these guidelines: Initial (cold) start-up: Leave blower off until your stove is hot and a good coalbed is established. The blower may be turned on approximately 15 minutes after loading the stove with fuel.
  • Page 23: Maintenance: Creosote Removal

    MAINTENANCE and GLASS CARE CREOSOTE FIREBRICK When wood is The firebox of your Quadra-Fire stove is lined with high quality FORMATION AND NEED FOR REMOVAL: burned slowly, it produces tar and other organic vapors firebrick, which has exceptional insulating properties. There is no which combine with expelled moisture to form creosote.
  • Page 24: Brick Replacement

    4300 ACT Wood Stove Series BRICK REPLACEMENT INSTRUCTIONS The Step-Top Model accepts the Ash Removal System, The Millennium Model does not accept the Ash and the brick pattern incorporates the ash grate. Removal System. Brick Set Part 831-1960 Brick Set Part 831-1970 Brick Size Qty in Set Brick Size...
  • Page 25: Door Handle Assembly

    If your reason for removing the baffle is simply to clean the chimney, you have alternatives which will save time and effort. Call a qualified chimney sweep or an authorized Quadra-Fire dealer for details. 1. Remove all ash from the firebox, and extinguish all hot embers before disposal into a metal container.
  • Page 26: Exploded Views

    4300 ACT Wood Stove Series EXPLODED VIEWS Item Part Name Door, Cast Door Handle Glass, Replacement Glass Frame Assembly Glass Frame Screws (10) Hinge Pins Latch, Cam Latch Cam key Latch, Secondary 10 Locking Nut 11 Spring Handle, 1/2” 12 Trim for Door (Trim Door Assembly only) 13 Washer, Spacing DOOR, GLASS AND DOOR HANDLE ASSEMBLY...
  • Page 27: Accessory & Replacement Parts List

    4300 ACT Wood Stove Series ACCESSORIES 831-1671 ..Ash Removal System (ARS) 831-1701 ..Blower Assembly 832-1092 ..Door Assembly, Black 832-1912 ..Door Assembly, Gold Trim DR-31/43NL .
  • Page 28 4300 ACT Wood Stove Series NOTES Page 28 250-7061C December 10, 2004...
  • Page 29 4300 ACT Wood Stove Series NOTES 250-7061C December 10, 2004 Page 29...
  • Page 30: Service Maintenance And Log

    4300 ACT Wood Stove Series Service and Maintenance Log Date of Service Performed By Description of Service Page 30 250-7061C December 10, 2004...
  • Page 31: Warranty Policy

    4300 ACT Wood Stove Series Lifetime Warranty LIMITED LIFETIME WARRANTY The Hearth & Home Technologies limited Lifetime Warranty guarantees that the following components will work as designed for the lifetime of the stove or Hearth & Home Technologies will repair or replace them. These items include but are not limited to steel and cast iron components, all gas burners, gas logs, combustion chambers, heat exchanger systems, stainless steel firebox components, plating, doors, glass damaged by thermal breakage, steel baffle supports, steel and ceramic baffles and manifold tubes.
  • Page 32: Contact Information

    Hearth & Home Technologies 1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES www.quadrafire.com Please contact your Quadra-Fire dealer with any questions or concerns. For the number of your nearest Quadra-Fire dealer, call 1-800-926-4356 CAUTION • Do NOT discard this manual.