SCAN RESUME METHODS
Before using Scans other than Priority Scan, it's
necessary to decide under what condition you want your
transceiver to continue scanning after detecting and
stopping for a signal. You can choose one of the
following modes.
The default is Time-Operated mode.
e
Time-Operated mode
Your transceiver stops scanning when detecting a signal,
remains there for approximately 5 seconds, and then
continues to scan even if the signal is still present.
e
Carrier-Operated mode
Your transceiver stops scanning when detecting a signal
and remains on the same frequency until the signal drops
out. There is a 2 second delay between signal drop-out and
scan resumption to allow time for any responding stations to
begin transmitting.
¢ Seek mode
Your transceiver stops scanning when detecting a signal
and remains on the same frequency; the transceiver stays
on this frequency even after the signal drops out and does
not automatically resume scanning.
Note: Pressing and holding [MONI] causes the transceiver to stop
scanning; releasing [MONI] causes it to resume scanning.
m@ Selecting Scan Resume Method
1
Press [F], [BAND] to enter Menu mode.
2
Select Menu No. 1 (SCAN).
mrcape
es
3
Press [BAND] to select Time-Operated (TO),
Carrier-Operated (CO), or Seek (SE) mode.
4
Press any key other than [BAND], [LAMP], and
[MONI] to exit Menu mode.