The Control Knob And Coffee Keys; The Boiler Pin - Philips Saeco XSmall Service Manual

Table of Contents

Advertisement

XSMALL
7.3. The control knob and coffee keys
To remove the coffee keys from the control
keypad, detach them from the anchoring
device on the back of it and take them out.
XSmall Puro
To remove the coffee keys from the control
keypad, detach them from the anchoring
device on the back of it and take them out.
1
7.4.

The boiler pin

Boiler pin (Vapore)
Loosen the screws shown
and remove the boiler
pin.
Disassembling the power P.C.B.
To reprogram the P.C.B. connect the S.S.C
1) Loosen the screw shown and remove
the P.C.B. protection.
2) Slide out the P.C.B., removing all
connections.
2
Boiler pin (Puro)
Loosen the screw and
remove the boiler pin.
To remove the knob, simply
slide it out of its position.
Remove the OETIKER clamp and
pull out the silicon tube
07 DISASSEMBLY