XSMALL
Level 3 (Grinder-Heater)
Start condition
Action by user
The user checkers that the absorbed current is OK
ERROR: the absorbed current is KO; check the wiring from the hea-
ter to the CPU/POWER board (JP17-3) and the other wiring
The led alarm flashing for 3 sec.
ERROR: the led alarm remains OFF; check the hall sensor board in
the Grinder, the Grinder, the wiring from the hall sensor board to the
CPU/POWER board (JP2) and the wiring from the Grinder to the CPU/
POWER board (JP8)
Finish condition

5.2.1. Steam Out

This document describes the procedure of SteamOut in XSmall Evo machine. This application is used
in order to empty the boiler.
MACHINE UNPLUGGED
The machine enters in SteamOut mode by moving the knob in the water position
then pushing the COFFEE button,
and then connecting the machine to the plug.
As long as the COFFEE button is pressing the machine shows all LEDS ON: Led Temp, Led Double
Coffee, Led Alarm. Led NO_Water.
When the COFFEE button is release the machine starts the Steam Out: Led Temp, Led Double
Coffee, Led Alarm, Led No_Water flashing with anticlockwise rotation.
When the steam out procedure is completed the Led Temp, Led No_Water and Led Double Coffee
switch on.
The user must close the tap and the Led Double Coffee switch off.
Now is possible to switch off the machine or repeat the procedure pressing and releasing the COFFEE
button.
Press the coffee button to switch on the heater
Press the coffee long button to switch on the grinder
05 SERVICE MODE
LED INDICATION
Led Temp
Led Alarm
OFF
LED INDICATION
Led Temp
Led Alarm
OFF
OFF
OFF
Flashing
OFF
LED INDICATION
Led Temp
Led Alarm
OFF
OFF
OFF
OFF
OFF
OFF
07/20