7. Take off compressor screws.
REPLACING SOLENOID VALVES
Unplug the power cord before servicing.
Parts may be ordered at Hussmann's Performance
Parts e-store:
https://parts.hussmann.com/
Call toll free: 855-487-7778
or
Required Tools:
• Screwdriver / Philips Tip
• 1/4" Allen Wrench
• Copper Tubing Cutter
• Blow Torch
1. Remove product and place in a refrigerated
area. Make sure the power is off to the
case.
2. Make sure there is no voltage in the
refrigerator. Remove rear lower panel.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
8. Remove welded joints to the compressor
and replace with new compressor.
9. Reverse the process and make sure
everything is in place.
3. Make sure there is no refrigerant left in the
system.
4. Slide out the condensing unit. Be careful
using the condensing unit base to pull it
out. Make sure not to stress or interfere
with other parts.
3VRLB1A Shown