Hussmann VRL Installation & Operation Manual page 16

Low temperature self contained glass door merchandisers with r-290 refrigerant
Table of Contents

Advertisement

E
16
lEctrIcal
ELECTRICAL / REFRIGERATION / CONTROLLER
PLUG
These merchandisers use a single, 9 ft. power
cord and plug.
1 and 2-door case models use a NEMA 5-15P
(plug). 3-door models use a NEMA 5-20P.
The plug is located on the right-hand side at the
rear of the merchandiser.
Disconnect power before servicing. VRL
merchandisers require a dedicated electrical
circuit with ground. 12AWG is the minimum-
sized acceptable wire.
• Always use a dedicated circuit with the
amperage stated on the unit.
• Plug into an outlet designed for the plug.
• Do not overload the circuit.
• Never use extension cords or adapters.
• If in doubt, call an electrician.
Merchandiser must be grounded.
Do not remove the power supply cord ground.
NOTES:
1. APPLICABLE STANDARDS / SPECIFICATIONS
ASME Y14.5M-1994, DIMENSIONS AND TOLERANCES
2. KEY PRODUCT CHARACTERISTICS PER EPR-0006 & IDENTIFIED WITH SYMBOL
3. MATERIAL-
4. REF -
PN_3155541_E
/ r
EfrIgEratIon
— LOCK OUT / TAG OUT —
To avoid serious injury or death from electrical shock, always
disconnect the electrical power at the main disconnect when
servicing or replacing any electrical component. This includes,
but is not limited to, such items as doors, lights, fans, heaters,
and thermostats.
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
/ c
ontrollEr
Nominal
Minimum
Voltage
110-120
ALWAYS CHECK THE SERIAL PLATE FOR
COMPONENT AMPERES
NEMA 5-15P
115V 60Hz
NEMA 5-15P
(1 and 2-door
case models)
115V 60 HZ
Risk of Electric Shock. If cord or plug
becomes damaged, replace only with
a cord and plug of the same type.
K
Maximum
Voltage
Voltage
110
120
NEMA 5-20P
115V 60Hz
(3-door case
models)