Low temperature self contained glass door merchandisers with r-290 refrigerant
Table of Contents

Advertisement

PN_3155541_E
Do NOT Use:
• Abrasive cleansers and scouring pads,
as these will mar the finish.
• Coarse paper towels on coated glass.
• Ammonia-based cleaners on acrylic parts.
• A hose on lighted shelves or submerge the
shelves in water.
• Solvent, oil or acidic based cleaners on any
interior surfaces.
• A hose on rail lights, canopy lights or any
other electrical connection.
Do:
• First turn off refrigeration, then disconnect
electrical power.
• Remove product and loose debris.
• Thoroughly clean all surfaces with soap
and hot water. d
o not use steAm or
high wAter pressure hoses to wAsh the
. t
interior
hese destroy merchandiser
sealing causing leaks and poor
.
performance
• Take care to minimize direct contact between
fan motors and cleaning or rinse water.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
• Rinse with hot water, but do NOT flood.
• Allow merchandiser to dry before resuming
operation.
• Wipe down lighted shelves with a damp
sponge or cloth so that water does not enter
the light channel. d
submerge shelves in wAter
• After cleaning is completed, restore power
and turn on the merchandiser.
Product will be degraded and may spoil if
allowed to sit in a non-refrigerated area.
Cleaning Shelves
Shelves and shelf clips are easily removed for
cleaning the interior as well as the shelves
themselves.
'
s
o not use A hose or
.
VRL Merchandisers
37