MCZ CLUB COMFORT AIRMATIC 14 M2 Operation And Cleaning page 65

Sealed pellet stove
Hide thumbs Also See for CLUB COMFORT AIRMATIC 14 M2:
Table of Contents

Advertisement

35-CLEANING
SHUTDOWN (end of season)
At the end of each season, before switching the product off, it is recommended to remove all the pellets from the hopper with a vacuum
cleaner with a long pipe.
We recommend removing the unused pellets from the hopper because they can retain moisture. Disconnect any combustion air ducting
that can lead to moisture inside the combustion chamber but, above all, ask the specialised technician to refresh the paint inside the
combustion chamber with the special silicone spray paints (available at any store or Technical Assistance Centre) during the necessary
annual end of season scheduled maintenance operations. This way the paint will protect the inner parts of the combustion chamber,
blocking any type of oxidative process.
When not in use the appliance must be disconnected from the mains power supply. It is recommended to remove the
power cable for additional safety, especially in the presence of children.
The service fuse may have to be replaced if the control panel display does not switch on when the product is switched on again by pressing
the main switch on its side.
There is a fusebox on the side of the product, near the power socket. Open the fusebox cover with a screwdriver and replace the fuses if
necessary (3.15 A delayed) - seek assistance from an authorised and qualified technician.
CHECKING THE INTERNAL COMPONENTS
ATTENTION!
The internal electromechanical components must only be checked by qualified personnel whose technical expertise
includes combustion and electricity.
We recommend for this yearly maintenance to be carried out (with a scheduled service contract). This operation consists of a visual and
functional inspection of the internal components. A summary of the checks and/or maintenance operations that are essential for the
correct operation of the product is provided below.
PARTS/FREQUENCY
Lower compartment*
Glass
Air filter
Upper exchanger
Lower exchanger
Smoke duct
Gaskets
Door closure operation
* Cleaning of the lower compartment depends on various factors (pellet type, stove power, stove use, type of installation...); the exact
emptying time will be suggested by experience.
Technical Dept. - All rights reserved - Reproduction prohibited
Brazier
Ash compartment
Ash pan area
2-3 DAYS
15/20 DAYS
·
·
·
1 YEAR
·
·
·
·
·
65