33-ALARMS
ALARM SIGNALLING
If an operating anomaly occurs the stove starts switching off due to the alarm.
The following table describes the possible alarms indicated by the stove, associated to the respective code that appears on the emergency
panel and helpful tips to solve the problem.
MESSAGE ON DISPLAY
A01
FAILED IGNITION
A02
NO FLAME
A03
PELLET SAFETY
A04
SMOKE OVERTEMPER-
ATURE
A05
OBSTRUCTION
A08
FUMES MOTOR FAULT
A09
THERMOCOUPLE FAULT
A11
FEED SCREW FAULT
50
TYPE OF PROBLEM
The flame does not ignite
The fire goes out abnormally
The temperature of the pellet hopper
exceeds the required safety threshold.
The structure overheats due to reduced
heat dissipation.
The temperature of the exhaust smoke has
exceeded certain preset safety limits.
Flue clogged - wind.
The smoke extractor fails to guarantee
sufficient primary air, required for correct
combustion.
Abnormal operation of smoke fan
The smoke probe is faulty and does not
detect the exhaust smoke temperature
properly.
Pellet supply fault
SOLUTION
Check the level of pellets in the hopper.
Check that the brazier is correctly positioned in its seat
and has no deposits or unburnt material.
Make sure the glow plug warms up.
Carefully empty and clean the brazier before restarting.
Check the level of pellets in the hopper.
Check that the brazier rests correctly in its seat and has no
visible deposits of unburnt pellets.
The structure is too hot because the product has been
used for too long at the maximum power or there is poor
ventilation. When the stove is cold enough, press the
button for at least 3" to reset the alarm. Once the alarm is
cleared, the product can be switched on normally.
The stove switches off automatically. Let the stove cool
down for a few minutes and then switch it on again.
Check the smoke expulsion and verify the type of pellets
used according to the instructions found in Chap. 2 of this
manual.
Check the smoke duct and make sure the door is closed.
Draught difficulties or clogged brazier.
Check whether the brazier is clogged and clean it, if
necessary.
Check, and if necessary clean, the smoke duct and the air
inlet.
Check cleanliness of the smoke fan compartment and
check whether dirt is blocking it. If this is not enough, the
smoke fan is faulty. Contact an authorised service centre
to have it replaced.
Contact an authorised service centre to have the
component replaced.
Contact an authorised service centre to have the
component replaced.