Problems resolved in this release: 4.2.2
Q01827696
NSF allows users to configure same IP address for two different interfaces (though with
different mask.). In iSD, the configuration is getting applied successfully but failed to get
applied at the accelerator. Gradually accelerators move to Accel-OFF state and no more
configurations can be applied at the accelerator. This issue is fixed in 4.2.2 release by
adding a validation not to allow same IP addresses for different interfaces.
Q01834805 After configuring the management IP and sync interface, the directors will go
reboot. Once the directors come up and if no accelerators are connected at that time, the
management IP configuration is lost. This is caused due to a validation in the configuration
module which returns without applying the config if no active accelerators are found. This
issue is fixed in 4.2.2 release by removing the validation in the configuration module
Q01855791 L2FW over trunked ports doesn't work as desired and regular traffic is affected.
issue is caused by invalid FDB lookup which didn't consider the trunked ports scenario in
L2FW configuration. This issue is fixed in 4.2.2 release by including the trunked ports
while doing the FDB lookup.
Q01747321 With certain fctl settings on the dual ports (ports 3-6), some times port status on the
backup accelerator are shown as "Link up but Blocking" mode. Although it's not
consistent, issue was also seen by constantly changing the various port configurations and
alternating between the preferred & backup settings. The issue is caused due to invalid
updation of dual port's flag status by MP. This issue is applicable for SFA model 6600
only.
This issue is fixed in 4.2.2 release by correctly updating the flag status with the configured
port settings.