Installation and break-in procedures
Location of the air compressor
Locate the air compressor in a clean, dry and well-ven-
tilated area. The air filter must be kept clear of obstruc-
tions, which could reduce air delivery of the air compres-
sor. The air compressor should be located at least 305
mm away from the wall or other obstructions that will
interfere with the flow of air. The air compressor head
and shroud are designed to allow for proper cooling.
If humidity is high, an air filter can be installed on the air
outlet adapter to remove excessive moisture. Follow the
instructions packaged with the air filter for proper installation.
Place the air compressor on a flat surface so that it is
resting securely on the rubber feet.
WARNING:
Risk of Falling
WHAT CAN HAPPEN
The air compressor can fall from a table, workbench,
or roof causing damage to the compressor and could
result in serious injury or death to the operator.
HOW TO PREVENT IT
Always operate compressor in a stable secure
position to prevent accidental movement of the com-
pressor. Never operate compressor on a roof or other
elevated position. Use additional air hose to reach
high locations.
Please see the chart below for the MINIMUM extension cord gauge requirements:
Amp Rating
Range (220 -
10m
240 V)
0 - 5 A
1.5 mm
5 - 8 A
1.5 mm
8 - 12 A
2.5 mm
Amp Rating
Range (110 V)
10m
0 - 5 A
1.5 mm
5 - 8 A
1.5 mm
8 - 12 A
2.5 mm
12 - 15 A
4 mm
15 - 20 A
6mm
Piping
Plastic or PVC pipe is not designed for use with com-
pressed air. Regardless of its indicated pressure rating,
plastic pipe can burst from air pressure. Use only metal
pipe for air distribution lines. If a pipe line is necessary,
use pipe that is the same size, or larger than, the air
tank outlet. Piping that is too small will restrict the flow
of air. If piping is over 30.5 m long, use the next larger
size. Bury underground lines below the frost line and
avoid pockets where condensation can gather and
freeze. Apply pressure before underground lines are
covered to make sure all pipe joints are free of leaks.
15m
2
2
1.5 mm
2
2
1.5 mm
2
2
2.5 mm
15m
2
2
1.5 mm
2
2
1.5 mm
2
2
2.5 mm
2
2
4 mm
2
2
6mm
Operating temperature
The operating temperature of this compressor is
between 0°C and 40°C.
CAUTION:
the temperatures below 0°C and above 40°C.
Duty cycle
All Makita manufactured air compressors are recom-
mended to be operated on not more than a 50% duty
cycle. This means an air compressor that pumps air more
than 50% in one hour is considered misuse because the
air compressor is undersized for the required air demand.
Power supply
Operate the compressor at voltages specified on the
nameplate, the allowable tolerance range must remain
within ±5%. If using the compressor at a higher voltage
than the rated voltage, it will result in abnormally fast motor
speed and may damage the unit and burn out the motor.
Extension Cords
To avoid voltage drop, power loss, and overheating of
the motor, use extra air hose instead of an extension
cord. Low voltage can cause damage to the motor.If an
extension cord must be used:
Make sure the extension cord is in good condition.
Total Length of Cord in Meter
20m
30m
2
1.5 mm
2.5 mm
2
2.5 mm
4 mm
2
4 mm
Not
Recommended
Total Length of Cord in Meter
20m
30m
2
1.5 mm
2.5 mm
2
2.5 mm
4 mm
2
2
4 mm
6mm
2
2
6mm
6mm
2
6mm
Not
Recommended
DANGER:
in electrical shock. Do not modify the plug that
has been provided. If it does not fit the available
outlet, the correct outlet should be installed by a
qualified electrician.
8 ENGLISH
Never operate the compressor in
50m
2
2
4 mm
2
2
4 mm
Not
Recommended
50m
2
2
4 mm
2
2
6mm
Not
Recommended
Not
Recommended
Not
Recommended
Improper grounding can result
60m
2
4 mm
2
4 mm
Not
Recommended
60m
2
4 mm
Not
Recommended
Not
Recommended
Not
Recommended
Not
Recommended