Out Of Range Feature - Crestron STX-1700CXP Operation Manual

2-way rf wireless touchpanel
Hide thumbs Also See for STX-1700CXP:
Table of Contents

Advertisement

2-Way RF Wireless Touchpanel
28 • 2-Way RF Wireless Touchpanel: STX-1700CXP
STX-1700CXP Troubleshooting (continued)
POSSIBLE
TROUBLE
CAUSE(S)
Touchpanel display is
Standby or power
dark.
down timeout has
elapsed.
No power to the
touchpanel.
One or more "quick"
Unit out of range.
pushbuttons do not
Refer to "Out of
function as expected.
Range Feature" on
page 27.
Wrong SIMPL
Windows program
uploaded.
Touchpanel operation
Touchpanel is out of
appears unreliable.
range. Refer to "Out
of Range Feature"
below.
RF Interference
Code related issues
Touchpanel does not
Touchpanel RF ID is
function and SIG LED
not set to match the
on TPS-RFGWX
RF ID assigned in the
illuminates, but Rx or
control system
Tx LEDs do not.
program.
SIG LED on TPS-
RF channel of
RFGWX does not
Touchpanel and
illuminate.
channel ID of TPS-
RFGWX receiver do
not match.
Touchpanel screen
Touchpanel went out
changes without
and then in range
touching screen or
while control system
buttons.
changed a screen.

Out of Range Feature

The out of range feature is always active. It is up to the programmer to provide an
indication on the touchpanel.
When the STX-1700CXP is out of range, it displays an out of range indication of
your choice (refer to "Reserved Join Numbers" on page 19), and the touchpanel does
not respond. Also, the TPS-RFGWX's Tx (transmit) LED will flash every four to
five seconds for approximately 30 seconds and then the LED stops flashing (the unit
stops transmitting if the touchpanel does not come into range in the allotted time). If
the touchpanel comes into range before the TPS-RFGWX stops transmitting, the
display reverts to whatever screen the control system has active. If the touchpanel
comes into range after the TPS-RFGWX stops transmitting, the user must touch the
screen to activate the gateway and leave the out of range screen.
Crestron STX-1700CXP
CORRECTIVE ACTION
Touch screen to reactivate.
Verify the power is properly applied and all
connections are made.
Bring unit in range.
Upload correct SIMPL Windows program.
Refer to the SIMPL Window help file for more
information.
Bring unit within range. Refer to
"Specifications" for details.
Use reserved join number 17509 in SIMPL
Windows program to indicate when touchpanel
is out of range.
Install an additional TPS-RFGWX near the
area of use to accommodate roaming.
Test as wired unit. If unit tests OK as wired
touchpanel, and fails as wireless touchpanel,
call Crestron Customer Service.
Test as wired unit. If unit tests OK as wired
touchpanel, and fails as wireless touchpanel,
call Crestron Customer Service.
Verify that RF IDs match. Refer to the "Select
Interface" on page 8 for details and RF ID
parameters assigned in the program.
Verify that RF channel matches channel ID of
TPS-RFGWX. Refer to the "Select Interface"
on page 8 for details and RF ID parameters
assigned in the program.
Use reserved join number 17509 in SIMPL
Windows program to indicate when touchpanel
is out of range.
Operations Guide - DOC. 6144