Changing the AC Input Voltage Setting and the
Fuses
If needed, change the AC input voltage setting (voltage selector switch) and both
fuses from 115 V AC to 220 V AC operation:
1. Make sure the power cord is removed from the scanner.
2. Insert a straight-blade screwdriver into the locking tab to open the AC input
3. Using your fingers (or, if needed, needle-nose pliers), remove the voltage
4. Orient the voltage selector switch with 220 V AC facing you and insert it into
May 2002
module.
selector switch.
the AC input module.