Part 1: Mount The Device - Juniper PTX10001 Quick Start Manual

Advertisement

Management host, such as a PC laptop, with a serial port (not provided)
(Optional) Grounding cable kit with bracket, lug, and three screws. To install the grounding cable, see the PTX10001
documentation at
https://www.juniper.net/documentation/product/en_US/ptx10001

Part 1: Mount the Device

The PTX10001 can be mounted in a 19-inch four-post rack.
To mount the device in a standard 19-inch rack:
1. Attach the ESD grounding strap to your bare wrist and to a site ESD point.
NOTE:
If you are mounting multiple units in the rack, mount the heaviest unit at the bottom and mount the
others from bottom to top in order of decreasing weight. The PTX10001-20C weighs approximately 26.8 lbs
(12.2 kg). Installing the router in a rack requires two people to lift the device and secure it to the rack.
2. Place the rack in its permanent location, allowing adequate clearance for airflow and maintenance, and secure it to the
building structure.
3. Determine whether the end with field replaceable units (FRUs) or the ports are to be placed at the front of the rack.
4. Align the holes in the mounting-rail with the holes on the side of the chassis.
5. Attach the mounting-rail to the router using six mounting screws.
ALM
SYS
ID
CON
ALM
SYS
ID
MGMT
CON
MGMT
0
1
2
3
4
5
6. Repeat Step 4 and Step 5 on the opposite side of the router.
7. Have one person grasp both sides of the router, lift it, and position it in the rack so that the front bracket is aligned
with the rack holes.
8. Have a second person secure the front of the router to the rack using four mounting screws (and cage nuts and washers
if your rack requires them.) Tighten the screws.
0
6
1
7
2
8
3
9
4
10
5
11
6
12
7
13
8
14
9
15
10
16
11
17
12
18
13
19
14
15
16
17
18
19