SMC Networks ISE20B Operation Manual page 81

Digital pressure switch
Hide thumbs Also See for ISE20B:
Table of Contents

Advertisement

Problem
Problem
No.
Copy error [Er13]
is displayed on
18
the copy
destination
pressure switch.
The operation is
19
unstable.
(chattering)
Problem possible
causes
(1) Check the wiring connection at
the FUNC terminal.
Incorrect wiring
Check the power supply wiring.
(2) Check the lead wire lengths.
The model number of the copy
Improper model
source Pressure switch and the copy
selected
destination Pressure switch are
different from each other.
Too many
pressure
Check the number of connected copy
switches
destination Pressure switches.
connected
Product failure
Effect of line
pressure
fluctuation
(1) Check the set pressure values
because
(hysteresis)
hysteresis is too
(2) Check the delay time.
narrow or delay
time of the switch
is too short
(1) Check the power supply wiring.
Incorrect wiring
(2) Check if there is bending stress
or broken lead
applied to any parts of the lead
wire
wire.
Product failure
-81-
Investigation method
Countermeasures
(1) Correct the wiring.
(2) The maximum
transmitting distance of
the copy function is 4 m.
Shorten the lead wire to
4 m or less.
Check the model numbers.
Copying is available when
the pressure range, output
specification and units
specification are identical.
The number of connected
products for which copying is
possible is up to 10 pcs.
Reduce the number to 10
pcs. or less.
Replace the product.
(1) Check the pressure
setting.
(2) Reset the function
settings.
(1) Correct the wiring
(2) Correct the wiring
conditions (reduce the
tensile force and
increase the bending
radius).
Replace the product.
No.PS※※-OMU0006-F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zse20fZse20b

Table of Contents