Conditions and explanations for auto-shift function
•Maintain a constant pressure for 5 ms or longer from the end of the auto-shift input signal.
•The sub screen displays "ASin ooo" for approximately 1 second during auto-shift input, and the pressure
value is stored as the corrective value "C_5".
•With the corrected value stored, the set value is compensated.
•When the set value is corrected, the switch output will operate in accordance with the delay time, within 5
ms after the auto-shift input.
•If the measurement pressure during the auto-shift input operation exceeds the set pressure range, the
corrected value will not be stored, but "ASin o.r" will be displayed on the sub screen for approximately 1
second.
•If the measurement value during auto-shift input is within the set pressure range, and the set value
corrected by auto-shift (including hysteresis) exceeds the set pressure range, the set value will be
corrected to the upper or lower value (whichever is closer).
(The correction is performed when the auto-shift input is applied at the pressure beyond the set pressure
range. If the auto-shift input is applied again at the pressure within the set pressure range, the correction
is released and the product operates according to the set value).
•The corrected value memorized on "C_5" can be displayed on the sub screen in measurement mode.
(Refer to "Sub display" on page 51.)
•The corrected value [C_5] after auto-shift input will disappear when the power is turned off, and will reset
to zero (initial value) when the power is returned.
Using the auto-shift input, the acceptable set range is as follows:
Range
Compound pressure
Positive pressure
Vacuum pressure
Setting of effective output
Press the
or
button to select the effective
output.
Press the
button to set.
[F 5] FUNC terminal setting completed
Set pressure range
Acceptable set range
-105.0 to 105.0 kPa
-210 to 210.0 kPa
-0.105 to 1.050 MPa
-1.155 to 1.155 MPa
10.0 to -105.0 kPa
-115.0 to 115.0 kPa
Return to function
selection mode.
-48-