SMC Networks ISE20B Operation Manual page 14

Digital pressure switch
Hide thumbs Also See for ISE20B:
Table of Contents

Advertisement

Term
D
Delay time
digit (Min. setting unit)
Digital filter
Display accuracy
Display color
Display resolving power
Display value fine adjustment
(function)
E
Error displayed
Error output
F
F.S.
(full span/full scale)
Fine adjustment mode
Fluid contact part (or wetted
part)
Function selection mode
The setting time from when the pressure applied to the pressure switch
reaches the set value, to when the ON-OFF output actually begins working.
Delay time setting can prevent the output from chattering.
Shows how precisely the pressure can be displayed or set by the digital
pressure switch. When 1 digit = 1 kPa, the pressure is displayed in
increments of 1 kPa, e.g., 1, 2, 3, ..., 99, 100.
Function to add digital filtering to the fluctuation of pressure value. Smooth the
fluctuation of displayed value for sharp start up or fall of the pressure.
When the function is valid, digital filtering is reflected to the ON/OFF of the
switch output.
Output chattering or flicker in the measurement mode display can be reduced
by setting the digital filter.
The response time indicates when the set value is 90% in relation to the step
input.
Shows The maximum deviation between the displayed pressure value and
the true pressure.
Indicates the color of the number of digital display. Always green, always red,
green (switch OFF) → red (switch ON), red (switch OFF) → green (switch
ON) are available.
Indicate in how many the rated pressure range can be divided to display.
(Example: When the value can be displayed down to 0.001 MPa for the
product for 0 to 1 Mpa, the resolution is 1/1000)
Displayed pressure value can be adjusted within the range of 5%R.D. (5%
of displayed value). It is used if the true pressure value is known, or to
eliminate differences between the displayed values of different instruments
that are measuring the same pressure.
The code number displayed, identifying the error detected by the
self-diagnosis function of the pressure switch.
Refer to "Error indication function" on page
Switches the switch output to ON/OFF when an error is displayed.
Refer to "List of output modes" on page
Refer to "Error indication function" on page
Abbreviation of full span and full scale; difference between the minimum and
maximum rated pressure values. means the maximum fluctuation range of
the pressure switch rated value.
For example, when the rated pressure range is -0.100 to 1.000 [MPa]:
F.S. = 1.000 - (-0.100) = 1.100 [MPa]
(Reference: 1%F.S. = 1.100 x 0.01 = 0.011 [MPa])
Refer to "Display value fine adjustment (function)".
Part of the pressure switch which contacts detected fluid. Pressure sensor,
seal and fitting are included.
A mode in which setting of functions is performed. It is a separate menu from
the pressure setting. If any function settings need to be changed from the
factory default, each setting can be selected with "F".
The setting items are: operation mode, output type, display color, digital filter,
use of auto preset, analog/auto shift/copy, display value fine adjustment, sub
screen display, display resolution, use of power saving mode and use of
security code.
-14-
Definition
82
for details of the errors.
41
for operating conditions.
82
for details of the errors.
No.PS※※-OMU0006-F