Adjusting the color matching using a colorimeter
Use a colorimeter that can measure chromaticity coordinates and luminance to change the colors [RED],
[GREEN], [BLUE], [CYAN], [MAGENTA], [YELLOW], or [WHITE] to desired colors.
1)
Press as to select [COLOR MATCHING].
2)
Press qw to select [MEASURED].
3)
Press the <ENTER> button.
f The [MEASURED MODE] screen is displayed.
4)
Press as to select [MEASURED DATA].
f The adjustment condition can be reset by selecting [RESET]. For details regarding [RESET], refer to
"Resetting the adjustment condition of the color matching" (x page 124).
5)
Press the <ENTER> button.
f The [MEASURED DATA] screen is displayed.
6)
Measure the current luminance (Y) and the chromaticity coordinates (x, y) using the colorimeter.
7)
Press as to select a color, and press qw to adjust the setting.
f Set [AUTO TESTPATTERN] to [ON] to display a test pattern of selected colors.
8)
Once all the input is completed, press the <MENU> button.
f The [MEASURED MODE] screen is displayed.
f When [MEASURED] is selected in Step 2), proceed to Step 9) and enter the coordinates of desired colors.
9)
Press as to select [TARGET DATA].
10) Press the <ENTER> button.
f The [TARGET DATA] screen is displayed.
11) Press as to select a color and press qw to input coordinates for desired colors.
f By setting [AUTO TESTPATTERN] to [ON], the test pattern for the selected color is displayed.
12) Once all the input is completed, press the <MENU> button.
Note
f Colors are not displayed properly when target data is a color outside the region of this projector.
f Set the [AUTO TESTPATTERN] to [ON] to automatically display a test pattern for use in adjusting the selected adjustment colors.
f The [AUTO TESTPATTERN] setting will change in conjunction with the setting in the [ADVANCED MENU] menu → [EDGE BLENDING] →
[ON]/[USER] → [AUTO TESTPATTERN].
f When using a colorimeter or similar instrument to take measurement, measure the colors displayed in [AUTO TESTPATTERN].
f It is recommended to enter the value between [1000] and [32768] in [Y(RELATIVE)] of [WHITE] in the [MEASURED DATA] screen. For
each value ([Y(RELATIVE)] of [BLACK], [RED], [GREEN], and [BLUE]), enter the relative value for the [Y(RELATIVE)] value of [WHITE]
based on the luminance (Y) of each color measured using the colorimeter.
f A difference in the color coordinates of target data and measurement value obtained from an instrument may occur for certain instrument
and measurement environment used.
Resetting the adjustment condition of the color matching
Reset all the adjustment items of the color matching adjusted in [3COLORS], [7COLORS], and [MEASURED].
1)
Press as to select [COLOR MATCHING].
2)
Press qw to select [3COLORS], [7COLORS], or [MEASURED].
3)
Press the <ENTER> button.
f The [3COLORS], [7COLORS], or [MEASURED MODE] screen is displayed.
4)
Press as to select [RESET].
5)
Press the <ENTER> button.
f The confirmation screen is displayed.
6)
Press asqw to select [RESET].
124 - ENGLISH