Inspecting the Engine-Valve
Clearance
Service Interval: Every 800 hours
Inspect the engine-valve clearance. Refer to the
engine owner's manual.
Checking the Fuel Lines
and Connections
Service Interval: Every 400 hours
Inspect the fuel lines for deterioration, damage,
chaffing, or loose connections.
Electrical System
Maintenance

Electrical System Safety

Disconnect the battery before repairing the
machine. Disconnect the negative terminal first
and the positive last. Connect the positive terminal
first and the negative last.
Charge the battery in an open, well-ventilated
area, away from sparks and flames. Unplug the
charger before connecting or disconnecting the
battery. Wear protective clothing and use insulated
tools.

Servicing the Battery

DANGER
Battery electrolyte contains sulfuric acid,
which is fatal if consumed and causes severe
burns.
Do not drink electrolyte and avoid contact
with skin, eyes or clothing. Wear safety
glasses to shield your eyes and rubber gloves
to protect your hands.
Checking the Battery Charge
Service Interval: Monthly
Allowing the battery to stand for an extended
period of time without charging it results in reduced
performance and service life. To preserve optimum
battery performance and life, charge the battery in
storage when the open circuit voltage drops to 12.4 V.
Note:
To prevent damage due to freezing, fully
charge the battery before putting it away for winter
storage.
Check the voltage of the battery with a digital
voltmeter. Locate the voltage reading of the battery
in the table below and charge the battery for the
recommended time interval to bring the charge up to
a full charge of 12.6 V or greater.
Important:
Ensure that the negative (–) battery
cable is disconnected and the battery charger
used for charging the battery has an output of 16 V
and 7 A or less to avoid damaging the battery (see
the chart for the recommended charger settings).