5 CONTROLS

5.6.8 WARNING LOW HYDRAULIC OIL ________________________________________

When this screen is shown, the system has detected Low Hydraulic oil lev-
el in the tank. Stop the machine immediately and check for any hydraulic
oil leaks that need repair prior to topping up the hydraulic oil reservoir tank.

5.6.9 WARNING CHARGE FILTER BLOCKED ___________________________________

When this screen is shown, the hydraulic-charge filter is blocked and
needs replacing.
Replace the filter element at the earliest opportunity.

5.6.10 WARNING SERVICE REQUIRED _______________________________________

When this screen is shown, the machine needs a service. Refer to
section 6.4.1 to reset counter.
5.6.11 EMISSION FAULT – DELTA-P SENSOR OR ABNORMAL DELTA-P __________
When this screen is shown, the engine controller (ECU) is reporting an
abnormal DPF Differential Pressure or a fault with the sensor itself. The
output from the engine may be
possible and contact your local Jacobsen Dealer.
en-42
reduced.
Stop the engine as soon as
1/1