Cross Cut; Inclinometer; Set Default Parameters - Jacobsen JMP653F Manual

Kubota v2403-cr-te5, with reversing fan, 4wd with rops and cab
Table of Contents

Advertisement

5.5.9 CROSS CUT _________________________________________________________

Cross Cut function raises the cutting unit to a partially raised position,
allowing the operator to avoid obstructions without having to fully lift the
cutter deck. The Cutter PTO will disengage within 3 seconds of reaching
Cross Cut position. If lowered again within 2 minutes the Cutter PTO will re-
engage automatically. After 2 minutes of continued use in Cross Cut the
PTO will have to be manually reactivated using the PTO switch.
To activate Cross Cut, with the cutting unit in lowered position move the Lift
/Lower switch momentarily to the rear in a quick motion. To deactivate, move
the switch lever fully forward. refer to (section 6.7)
Using the PIN Menu Buttons 2 and 3 to arrow up and down, Button 4 to
select Cross Cut, this gives you the option to Enable or Disable
• Disabled - The unit will only lift while the lift joystick is held
• Enabled - The unit will lift to a predetermined height with a short single activation of the lift joystick.

5.5.10 INCLINOMETER _____________________________________________________

Using the PIN Menu Buttons 2 and 3 to arrow up and down, and
Button 4 to select Inclinometer and this gives you the option to Enable or
Disable TST™.
Note: If TST™ is installed, but disabled via the screen, the machine angle
when greater than 14° will be displayed, however no alarms or physical
interventions will occur.

5.5.11 SET DEFAULT PARAMETERS __________________________________________

The machine will have factory set
defaults. You can reset to factory
settings by Using the PIN Menu
Buttons 2 and 3 to arrow up and
down, and Button 4 to select Set
Default Parameters. Press arrow to
confirm.
Set Default Parameters
Press
To Confirm Set
To Default Parameter Values
CONTROLS 5
Cross Cut
Disabled
Enabled
Inclinometer
Disabled
Enabled
Set Default Parameters
Press
To Confirm Set
To Default Parameter Values
Are You Sure?
Yes
No